BLUE-WHITE PERISTALTIC METERING PUMPS
Blue-White’s FLEXFLO® Peristaltic Metering Pumps (Peristaltic Dosing Pumps) offer precise fluid metering and accurate dispensing with versatile control options. Their gentle, nearly pulsation-free action makes them ideal for challenging fluids such as gaseous chemicals, shear-sensitive substances, viscous slurries, solids, and low-moisture fluids. FLEXFLO® pumps feature Blue-White’s patented Tube Failure Detection System (TFD), ensuring reliable and safe operation by protecting your process from unexpected tube failures.
Features
- Self-priming – even against maximum line pressure. By-pass valves are not required
- Remote Start/Stop: Non-powered dry contact closure for remote start/stop
- 2 Year Warranty
- Heavy-duty rotor – single piece plastic rotor means no flexing and increased accuracy withno metal springs or hinges to corrode
Specifications
- Max Pressure: 100 psi
- Max Temperature: 185°F
- Max Viscosity: 5000cP
- Max Suction lift: 30 FT
Features
- Tube Failure Detection (TFD) senses tube rupture, preventing hazardous chemical spills
- NEMA 4X (IP66) wash-down, chemically resistant powder coated enclosure
- No false triggering – Patented
- Optional dual channel tube design for optimum performance and pressure capability
Specifications
- Max Pressure: 125 psi
- Max Temperature: 185°F
- Max Viscosity: 12000cP
- Max Suction lift: 30 FT
Features
- 5” touchscreen color LCD display
- Optional dual channel tube design for optimum performance and pressure capability
- 2,500:1 turndown ratio
- Security programmable 6-digit password to prevent tampering
Specifications
- Max Pressure: 125 psi
- Max Temperature: 185°F
- Max Viscosity: 12000cP
- Max Suction lift: 30 FT
Features
- Tube Failure Detection (TFD) senses tube rupture by detecting chemical in the pump head. No false triggering – Patented
- Optional dual channel tube design for optimum performance and pressure capability
- 2,500:1 turndown ratio
- No false triggering – Patented
Specifications
- Max Pressure: 125 psi
- Max Temperature: 185°F
- Max Viscosity: 12000cP
- Max Suction lift: 30 FT
Features
- Tube Failure Detection (TFD) senses tube rupture by detecting chemical in the pump head
- 2,500:1 turndown ratio
- Exclusive offset-roller design reduces pulsation by up to 80%
- NEMA 4X wash-down, chemically resistant enclosure
Specifications
- Max Pressure: 65 psi
- Max Temperature: 185°F
- Max Viscosity: 12000cP
- Max Suction lift: 30 FT
Features
- Self-Priming against maximum line pressure
- Four pump tube material options: Norprene®, Norprene® Chemical, Tygothane®, and FKM
- Patented TFD (Tube Failure Detection) system protects against chemical spills from a worn out tube and activates an alarm output relay
- Cannot Vapor Lock or Lose Prime
Specifications
- Max Pressure: 100 psi
- Max Temperature: 130°F
- Max Viscosity: 5000cP
- Max Suction lift: 30 FT
Features
- Self-priming – even against maximum line pressure. By-pass valves are not required
- Lockout feature prevents any unwanted tampering – Patent pending
- CNC precision-machined squeeze rollers for optimum squeeze, unparalleled accuracy, and tube life
- 5 Year Warranty
Specifications
- Max Pressure: 100 psi
- Max Temperature: 185°F
- Max Viscosity: 5000cP
- Max Suction lift: 30 FT
Features
- Operator friendly digital controls with backlit LCD displays motor speed, input signal values, service, and alarm status
- 200:1 turndown ratio
- 5 Year Warranty
- Tube Failure Detection (TFD) senses tube rupture, preventing hazardous chemical spills
Specifications
- Max Pressure: 125 psi
- Max Temperature: 185°F
- Max Viscosity: 12000cP
- Max Suction lift: 30 FT
Features
- 10,000:1 turndown ratio
- Security programmable 6-digit password to prevent tampering
- Modular roller design allows for simple tube changes without needing a tool
- Optional dual channel tube design for optimum performance and pressure capability
Specifications
- Max Pressure: 125 psi
- Max Temperature: 185°F
- Max Viscosity: 12000cP
- Max Suction lift: 30 FT
Features
- Self-priming – even against maximum line pressure. By-pass valves are not required
- Cannot vapor lock or lose prime
- 10,000:1 turndown ratio
- Optional dual channel tube design for optimum performance and pressure capability
Specifications
- Max Pressure: 125 psi
- Max Temperature: 130°F
- Max Viscosity: 1000cP
- Max Suction lift: 10 FT
Features
- Peristaltic pump design does not have valves that can clog requiring maintenance
- Cannot vapor lock or lose prime
- Energy-efficient variable speed DC motor
- Specially engineered tubing for long life
Specifications
- Max Pressure: 40 psi
- Max Temperature: 125°F
- Motor: Brushless DC, 50W.
- Max Suction lift: 30 FT
Features
- Self priming – even against maximum line pressure. By-pass valves are not required
- Accurate adjustability touchpad and digital displa
- Patented safety switch ensures safety of operator during regular pump head maintenance
- Remote Start/Stop: Non-powered dry contact closure for remote start/stop
Specifications
- Max Pressure: 50 psi
- Max Temperature: 130°F
- Enclosure: NEMA 4X (IP66), Polyester powder coated aluminum
- Max Suction lift: 30 FT
Applications
- Precise output control to 20:1 turndown by means of dial knob
- 60-second repeating time cycle
- 3 – 60 second adjustable feed (injection) time per cycle
- Fixed-speed pump
Specifications
- Max Pressure: 100 psi
- Max Temperature: 130°F
- Max Viscosity: 5000cP
- Max Suction lift: 30 FT