­čô× +1 877-742-2878

FREE SHIPPING ON QUALIFYING ITEMS

FLOWLINE ECHOpod® dl14 ultrasonic level transmitter

The general purpose ultrasonic level transmitter provides continuous level measurement up to 49.2" (1.25m) with a 4-20mA signal output. It is configured via Flowline's free WebCal software. Each relay is fully configurable for automatic fill and empty or alarm functions. The embedded level controller may lower costs by replacing external control hardware. The Flowline EchoPod DL 14 Multi-Function Ultrasonic Liquid Level Sensor is a non-contact liquid level sensor that is well suited for corrosive, sticky, or waste liquids. This transmitter is selected for chemical feed, IBC or drum, skid or machine, and cooling tower applications.

Flowline echopod® dl14 ultrasonic level sensor success

Flowline EchoPod DL14 Ultrasonic Liquid Level Sensor is featured in what FOX News calls, "The greenest house in the world." Florida's Green House spotlights residential conversation technologies for EPA, university, engineer, and architect study. As the nation's water resources decline, reclamation is core to the solution. The average US citizen uses 88 gallons of water per day. About 65% of indoor use occurs in the bathroom and 1/3 of that flushes down the toilet. The GreenHouse reclamation system collects and filters gray water from sinks, showers, baths, laundry, and the yard for reuse in toilets and irrigation. The system includes a 120-gallon underground water cistern. The Flowline EchoPod DL14 Ultrasonic Liquid Level Sensor measures the level and opens the fill valve to replenish the system with tap water, if necessary.

Flowline echopod® dl14 ultrasonic level sensor features

  • Level measurement, switch, and control functions up to 9.8ÔÇÖ (3m)
  • Configuration is fast and easy via WebCal software and USB adapter
  • Narrow 2ÔÇŁ beam width and short 4ÔÇŁ dead band optimized for small tanks
  • Four programmable relays for switch, pump, or valve control and fail-safety
    • 1 pump or valve with 3 alarms
    • 2 pumps lead-lag with 2 alarms
    • 2 pumps duplexing with 2 alarms
    • 4 independent switch point alarms
  • PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
  • Automatic temperature compensation for accurate measurement

FLowline echopod® dl14 ultrasonic level sensor dimensions

flowline echopod® dl14 ultrasonic level sensor compatible products

flowline echopod® DL14 ultrasonic level sensor fittings

For optimum performance, install the Flowline Ultrasonic Level Sensor using the below recommended or direct equivalent fittings.

LM52-1400, LM52-1800, LM52-1410, LM52-1810, LM52-1850, LM50-1001-1

General Specifications for flowline echopod level transmitters

RANGE: 49.2" (1.25m)

ACCURACY: 0.125" (3mm)

RESOLUTION: 0.019" (0.5mm)

DEAD BAND:  2" (5cm)

BEAM WIDTH: 2" (5cm)

CONFIGURATION: WebCal PC Windows, USB 2.0

MEMORY: Non-volatile

SUPPLY VOLTAGE: 24 VDC (loop)

CONSUMPTION: 0.5W

LOOP RESISTANCE: 400╬ę max

SIGNAL OUTPUT: 4-20 mA, two-wire

SIGNAL INVERT: 4-20 mA or 20-4 mA

SIGNAL FAIL-SAFE: 4 mA, 20 mA, 21 mA, 22 mA, hold last

CONTACT TYPE: (4) SPST relays, 1A

CONTACT FAIL-SAFE: Power loss: Hold last, Power On: Open, close or hold last

HYSTERESIS: Selectable

PROCESS TEMP: F: 20┬║ to 140┬║, C: -7┬║ to 60┬║

TEMP COMP: Automatic

AMBIENT TEMP: F: -31┬║ to 140┬║, C: -35┬║ to 60┬║

PRESSURE: MWP = 30 PSI (2 bar)

ENCLOSURE RATING: Type 6P, encapsulated, corrosion resistant & submersible

ENCLOSURE MATERIAL: Polycarbonate

STRAIN RELIEF MATERIAL: Santoprene

TRANSMITTER MATERIAL: Polyvinylidene Fluoride

CABLE JACKET MATERIAL: Polyurethane

CABLE TYPE: 9-conductor, shielded

CABLE LENGTH: 48" (1.2m)

PROCESS MOUNT: 1" NPT (1" G)

MOUNT GASKET: Viton®

CLASSIFICATION: General Purpose

COMPLIANCE: CE, RoHS

APPROVALS: cFMus