The intrinsically safe 26 GHz pulse radar transmitter provides continuous level measurement up to 49.2' (15m) with a 4-20 mA signal output, and is configured via its integral push button display module or WebCal software. The non-contact solids level sensor is intended for dry solid media including aggregates, grains, pellets, powders and building materials. Select this sensor for easy process conditions with minimal dust and installation with an adjustable mounting bracket or gimbal flange. Typical applications include bins, transfer stations and crushers.
The LR97-S006 mounting bracket allows you to easily install and adjust the sensor angle for optimum placement relative to the materials angle of repose in installations without an enclosed top. Constructed of 304 stainless steel, the rugged bracket is widely used in crusher, transfer station, stockpile or open top bin applications.
FM and CSA approved intrinsically safe, the loop powered level indicator displays engineering units connected in series with one 4-20 mA level transmitter. Select the LI25-2001 level indicator for hazardous applications with an intrinsically safe sensor. For field mount installation, add a single or two indicator NEMA box.
RANGE: 12” to 49.2’ (30cm to 15m) |
FREQUENCY: 26 GHz |
ACCURACY: ± 10 mm |
DEAD BAND: 12” (30cm) |
BEAM ANGLE: 8º |
CONFIGURATION: Push button; WebCal® PC Windows® USB® 2.0 |
MEMORY: Non-volatile |
DISPLAY TYPE: LCD, dot matrix |
DISPLAY UNITS: Feet and meters |
DISPLAY BAR: Percent of span |
DISPLAY GRAPH: Echo signal curve |
SUPPLY VOLTAGE: 21.6 to 26.4 VDC |
MAX CONSUMPTION: 22.5 mA |
SIGNAL OUTPUT: 4-20 mA, two-wire |
SIGNAL INVERT: 4-20 mA, 20-4 mA |
SIGNAL FAIL-SAFE: 3.9 mA, 20.5 mA, 22 mA |
PROCESS TEMP: F: -40º to 392º, C: -40º to 200º |
TEMP COMP: Automatic |
STORAGE TEMP: F: -40º to 176º, C: -40º to 80º |
PRESSURE: -40: -14.5 to 580 psi (-1 to 40 bar), -44 & -45: Atmospheric |
ENCLOSURE RATING: IP67 |
ENCLOSURE MATERIAL: 316L stainless steel w/silicone gasket |
ENCLOSURE WINDOW MATERIAL: Polycarbonate |
CONDUIT ENTRANCE: (1) 1/2” NPT connector |
ANTENNA MATERIAL: 316L |
PROCESS MOUNT: -40: 1 1/2” NPT, -44: 4” gimbal flange (ANSI), -45: 5” gimbal flange (ANSI) |
CLASSIFICATION: Intrinsically safe |
CERTIFICATION: FCC, cTUVus |
COMPLIANCE: CE, RoHS |